Item
|
RS-DM60-160
|
RS-DM60-384
|
|
Detector characteristics
|
Detector type
|
Uncooled FPA microbolometer
|
|
Array size/format
|
160×120
|
384×288
|
|
Image manage
|
Field of view/min focus distance
|
18°×13°/0.3m
|
16°×12°/0.5m
|
|
Spatial resolutions(IFOV)
|
1.9mrad
|
0.88mrad
|
|
Thermal sensitivity
|
≤0.1@30℃
|
≤0.06℃@30℃
|
|
Frame rate
|
50/60HZ
|
|
Focus
|
Autom/manual electric focus
|
Autom/manual electric focus
|
|
Spectral range
|
8~14μm
|
|
Measurement
|
Temperature ranges
|
-20℃~+350℃,extend to +600℃
|
-20℃~+180℃,extend to +600℃
|
|
Accuracy
|
±2℃ or ±2% of reading, whichever is greater
|
|
|
Measurement correction
|
Automatic/manual
|
|
|
Measurement mode
|
Up to 4 movable spots. Up to 3 movable areas(maximum, minimum and average temperatures).Line profile. Isothem. Temperature difference.Alarm(voice,color)
|
|
Color palette
|
11 paletts changeable(Iron,Rainbow,Grey inverted,etc)
|
|
Image adjustment
|
Auto/manual gain and brightness
|
|
Setup functions
|
Date/time, temperature unit, language IP address
|
|
Emissivity correction
|
Variable from 0.01 to 1.0 or select from listings in pre-defined material list
|
|
Ambient temperature correction
|
Automatic correction according to user input
|
|
Atmospheric transmission correction
|
Automatic correction according to user input object distance, relative humidity, ambient temperature
|
|
Image storage
|
Raw image capture
|
Single frame raw image manual captured via client control software,the captured images are analyzable
|
|
Image storage
|
MPEG-4 images storage, single image capture,BMP
|
|
Power supply
|
Extermal power
|
10~15V DC
|
|
Power consumption
|
≤6W(Normal operating at 25℃ ambient temperature condition)
|
|
Environment
|
Operating temperature
|
-15℃~+50℃
|
|
Humidity
|
≤90% non-condensing
|
|
Physical characteristics
|
Weight
|
≤1.09Kg(Exclude lens)
|
|
Dimensious
|
224mm×92mm×82mm
|
260mm×92mm×82mm
|
|
Interface
|
Extermal DC input
|
Yes
|
|
Video output
|
PAL/NTSC
|
|
Digital video output
|
RJ-45 Ethernet output,MPEG4 digital video/raw temperature measured data
|
|
Remote control Interface
|
RS485
|
|
Ethernet interface
|
RJ-45 Ethernet output for thermal image, data transfer, and camera control
|
|
Alarm interface
|
Open/Close:Alarm signal output
|